1              INDEX

System Reguirements

Installation of SDK

Application development using SDK

On line help

Porting of Applications Developed by Other CE Versions

Other

 

2              System Requirements

BE-300.Net has the following system requirements:

l         A desktop computer with an x86-based microprocessor supported by Microsoft® Windows NT®. Microsoft recommends that your processor be equivalent to a 266-MHz Pentium II or above, 500-MHz is recommended.

l         Microsoft® Windows® 2000 or Windows XP or Windows ME.

l         128 MB of RAM. 192 MB of RAM is required to run the emulator.

l         300KB of available hard disk space for a typical.

l         A CD-ROM or DVD-ROM drive that is compatible with the multimedia desktop computer specification.

l         A monitor with VGA or higher resolution. Super VGA is recommended.

l         A Microsoft Mouse pointing device or compatible pointing device.

l         USB port to connect to your BE-300 device or LAN board connecting to your local net work.

 

3              Installation of SDK

The application which operates by BE-300.Net can be created in the environment developed to BE-300. (eMbedded Visual C++ 3.0 & BE-300 SDK)

However, CASIO_BE300NETSDK is required for the following processing.

l         On-line debugging

l         Development of the function added by BE-300.Net

3.1 Install "Microsoft eMbedded Visual C++ 4.0" (EVC4)

Please install eMbedded Visual C++ 4.0 in your PC first.

SDK released this time does not operate in eMbedded Visual C++ 3.0(EVC3).

eMbedded Visual C++ 4.0 can be downloaded from the following URL.

“http://www.microsoft.com/downloads/release.asp?ReleaseID=37662&area=search&ordinal=3”

(This URL may be changed.)

 

3.2 Install "CASIO_BE300NET_SDK.msi".

Please execute CASIO_BE300NET_SDK.msi on the PC on which you have installed EVC4.

(CASIO_BE300NET_SDK.msi is a self-extracting executable file)

This will install the CASIO BE-300 SDK so that applications can be built for the BE-300 using EVC3.

 

3.3 Programming option at EVC4

Please choose the following item the case where a new project is created, by EVC4.

CPUs: Win32 (WCE MIPSII)

Please choose CASIO_BE300NET as a platform after opening a project.

(Build -> Set Active Platform… -> CASIO_BE300NET)

 

 

4   Application development using SDK

4.1 Start "Microsoft eMbedded Visual C++ 4.0"

  If SDK installation has completed, CASIO_BE300 is added to the Platform.

 

4.2 Creation of project

  Choose "Win32 (WCE MIPSII)" at Selection of CPUs.

 

4.3 Setup of active Platform

  Choose CASIO_BE300 at setup of a menu "Build" / "Set Active Platform...".

 

4.4 Cautions at the time of building MFC project by MFC project

 When you build the Workspace and update the remote output file,

 download of mfcce300_ca.dll will be started. Please cancel it.

 mfcce300_ca.dll exists in the "\Program Disk" folder not in the

  "\Windows" folder.

 At the time of program run, it is loaded from a "\Program Disk" folder.

 In addition, please complete download of mfcce300_cad.dll without canceling

 at the time of debug. mfcce300_cad.dll does not exist in ROM.

 

 * Since mfcce300_ca.dll is arranged in this release at \Windows folder,

  the above-mentioned cautions are unnecessary.

 

4.5 Connection of ActiveSync

        "Top Menu" ->[Connections]->[PC Connect]->[Connect Now]

 

  Default: it is a setup connected by USB.

 

  When connecting by USB,

    "Top Menu" ->[Connections]->[PC Connect]

  "USB Socket Default" is chosen as Commection method, and it once escapes

   by [O.K.].

  Please execute "ExeRepllog.exe".(manual:ExeRepllog.txt)

 

4.6 Use of remote tools

Setting:

 By each remote tools(menu "Tools"/ Remote Spy++, Remote Regisry ...),

 Menu "Connection" / "Configure Windows CE Platform Manager...",

 Select "CASIO_BE300BET/CASIO_BE300NET Device" and tap "Properties...".,

 Tap "Advanced" and select "Microsoft ActiveSync".

 

Connection:

 menu "Connection" / "Connect to Device" or "Add Connection,

 Select "CASIO_BE300NET/CASIO_BE300NET Device" and tap "OK".

 

5   On line help

 Please execute CasioAPIs.chm

 The functions added this time is the functions of Microsoft.

 This should look at a standard on line help.

 An additional function should look at "BE-300.Net Module and Component.pdf."

 

 

6              Porting of Applications Developed by Other CE Versions

 

l         Rebuild all applications using this SDK.

l         PocketPC(CE 3.00) applications need to be modified because not all of the PocketPC APIs are supported.

(i.e. aygshell.h, aygshell.lib are not included in this SDK)

 

7   Other

When using this SDK to develop an application for the CASSIOPEIA™ BE-300 Update, you can use the same steps as you would use when developing an application for a Pocket PC.

 


Copyright 2002 CASIO Computer Co., Ltd. All rights reserved.